Home > Products > Modular Din Rail Device
WPB1-63 MCB

WPB1-63 MCB

1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln, type D(10-16)ln

WPB2-63 Miniature Circuit Breaker

WPB2-63 Miniature Circuit Breaker

1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln, type D(10-16)ln

WPB3-63 Mini Circuit Breaker

WPB3-63 Mini Circuit Breaker

1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln, type D(10-16)ln

WPB9RL-100 New Design RCD

WPB9RL-100 New Design RCD

1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure

WPB8RL-100 6kA Economical RCCB

WPB8RL-100 6kA Economical RCCB

1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure

WPB1RL-100 Economical Residual Current Circuit Breaker

WPB1RL-100 Economical Residual Current Circuit Breaker

1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure

WPAF Series Arc Fault Detection Device (AFDD)

WPAF Series Arc Fault Detection Device (AFDD)

AFDD(arc fault detection device) is a new electrical anti-fireequipment. It could avoid various of fires caused by short circuit, circuit aging, heavy load,poor contact, fault electrical devices, etc. Automatic control is realized by built-in computer chip. Its operating principle: the detected arc impulse is processed, compared and identified by electronic circuit and MCU. Once fault arc impulse which easily creates fire detected, the output will drive tripping unit to cut off the load power supply, so that the fire is prevented.

Function
AFDD aims to detect hazardous arc impulse which easily creates fire(such as insulation decreasing between lines, load short circuit, poor contact of connector, arc caused by house electrical apparatus fault).Then it triggers tripping unit to cut off the power supply to prevent electrical fire. AFDDis used together with leakage circuit breaker, low voltage circuit breaker(overcurrent protection)tobuild a multi function electrical protective device. As a true intelligent low voltage electrical apparatus, t can not only prevent electrical fire, electric shock to human, overload danger, etc, but also be customized with different functions.

Application
As per IEC62606, these different ratings available: 10A, 16A, 20A, 32A, 40A, 63A ,usually used in residential houses as a terminal protective device. The applications of AFDD are wide, in theory, it can be used to avoid fire wherever there is electricity, such as in residential house, office building, hospital, shopping mall, supermarket, factory, vehicle(auto, train, vessel, air plane), especially for anti-fire use in residential house.




WPB2RL-100 Residual Current Circuit Breaker

WPB2RL-100 Residual Current Circuit Breaker

1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure

WPB5RL-100 Residual Current Circuit Breaker

WPB5RL-100 Residual Current Circuit Breaker


1. Protection against the effects of sinusoidal alternating earth fault currents

2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure

WPB6RL-100 Residual Current Circuit Breaker

WPB6RL-100 Residual Current Circuit Breaker

1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure

WPB7RL-100 Residual Current Circuit Breaker

WPB7RL-100 Residual Current Circuit Breaker

1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure

WPB6L-63 (Electromagnetic Type) RCBO

WPB6L-63 (Electromagnetic Type) RCBO

1. Protection against overload and short-circuit currents
2. Protection against the effects of sinusoidal alternating earth fault currents
3. Protection against indirect contacts and additional protection against direct contacts.
4. Protection against fire hazard caused by insulation faults
5. Used in residential building
6. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln

WPL360 Residual Current Circuit Breaker

WPL360 Residual Current Circuit Breaker

1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure

DZ47LE-125 Residual Current Circuit Breaker with Over Current Protection

DZ47LE-125 Residual Current Circuit Breaker with Over Current Protection

1. Protection against overload and short-circuit currents
2. Protection against the effects of sinusoidal alternating earth fault currents
3. Protection against indirect contacts and additional protection against direct contacts.
4. Protection against fire hazard caused by insulation faults
5. Used in residential building
6. According to the type of instantaneous release classified as follows : type C(5-10)ln, type D(10-20)ln

DZ47LE-63 Residual Current Circuit Breaker with Over Current Protection

DZ47LE-63 Residual Current Circuit Breaker with Over Current Protection

1. Protection against overload and short-circuit currents
2. Protection against the effects of sinusoidal alternating earth fault currents
3. Protection against indirect contacts and additional protection against direct contacts.
4. Protection against fire hazard caused by insulation faults
5. Used in residential building
6. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln

DZ30LE-32 Residual Current Circuit Breaker with Over Current Protection

DZ30LE-32 Residual Current Circuit Breaker with Over Current Protection

1. Protection against overload and short-circuit currents
2. Protection against the effects of sinusoidal alternating earth fault currents
3. Protection against indirect contacts and additional protection against direct contacts.
4. Protection against fire hazard caused by insulation faults
5. Used in residential building
6. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln

Busbar Pin PIN

Busbar Pin PIN

Material: Copper
Features: good conductivity, low contact resistance, safe and reliable performance.

Busbar Pin FORK

Busbar Pin FORK

Material: Copper
Features: good conductivity, low contact resistance, safe and reliable performance.

WPS6-D SPD

WPS6-D SPD

WPS6-D series Surge Protection Device is suitable for TT, IT, TN-S, TN-C and TN-C-S, the power supply system with the rated voltage up to 230/400V and AC 50/60Hz. Its design corresponds to IEC61643-1, GB18802.1 and GB50057. The product is usually installed in the incoming line low voltage distribution box of the building, and it can release 20kA lightning stroke current.
The lightning current SPD protection with protection level: III is applied to the Equipotential bonding when the lightning strike. WPS6-D Device should be installed in the boundary of LPZ1, LPZ2 and LPZn, usually in front of the residential distribution box, computer center, informational equipment, electronic equipment and controlling equipment or in the nearest socket box.

WPS6-C Surge Protector

WPS6-C Surge Protector

WPS6-C series Surge Protection Device is suitable for TT, IT, TN-S, TN-C and TN-C-S, the power supply system with the rated voltage up to 230/400V and AC 50/60Hz. It can work as the equipotential bonding when the lightning strike. Its design corresponds to IEC61643-1, GB18802.1 and GB50057.
The product is mainly applied to protect the low voltage electric equipment and prevent the surge causing by the thunder or switching overvoltage. As a univoltage limiting device, WPS6-C is equipped with the heavy-duty Zinc Oxide piezoresistor.
WPS6-C series (Protection level: II) Protection Device need to be installed on the up link of the equipment, connecting with outer conductor(L) or neutral conductor(N) and the earthing device. Users caninstall the WPS6-C in the boundary of LPZOA or LPZ1, usually in the incoming line low voltage main distribution box.