WPB9-63S 4.5kA Miniature Circuit Breaker
WPB9-63S series MCB with 4.5kA breaking capacity makes ideal for commercial and industrial applications. The products comply with IEC60898-1. #
WPB9-63N 6kA Mini Circuit Breaker
WPB9-63N series MCB with 6kA breaking capacity makes ideal for commercial and industrial applications. The products comply with IEC60898-1.MCB, mini circuit breaker, miniature circuit breaker
WPB9-63H 10kA High Breaking Capacity MCB
WPB9-63H series MCB with 10kA breaking capacity makes ideal for commercial and industrial applications. The products comply with IEC60898-1.Miniature circuit breaker, mini circuit breker, MCB
WPB9 MCB Accessories
This series circuit breaker accessories are used in household, building and other electrical circuits with WPB9 circuit breaker cooperated for remote control and different accessories selected for different needs, featured with auxiliary signal, opening and closing status indication, and even alarm signal function for better protection on the circuit, personal and property safety.
Standard: IEC60947-5-1
WPB9LE-100 Residual Current Circuit Breaker/RCCB/RCD
1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructureResidual current circuit breaker/RCCB/RCD
WPB9L-32 1P+N Electronic RCBO
WPB9L-32 1P+N Electronic RCBO
1. Protection against overload and short-circuit currents
2. Protection against the effects of sinusoidal alternating earth fault currents
3. Protection against indirect contacts and additional protection against direct contacts
4. Protection against fire hazard caused by insulation faults
5. Used in residential building
6. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln
WPB9E-63 36MM RCBO Electronic
1. Protection against overload and short-circuit currents
2. Protection against the effects of sinusoidal alternating earth fault currents
3. Protection against indirect contacts and additional protection against direct contacts
4. Protection against fire hazard caused by insulation faults
5. Used in residential building
6. According to the type of instantaneous release classified as follows : type B(3-5)ln, type C(5-10)ln
WPB9L-40 1P+N 36MM Electromagnetic RCBO
WPB9L-40 RCBO is an combined structure, the N pole is on the right side of the product.
Without auxiliary power supply, it overcomes the defects of electronic products: poor anti-interference, greatly affected by power grid voltage fluctuation and can't be protected if the neutral line is disconnected;
Test circuit is dynamic controlled, and the test resistance is not easy to burn;
N pole contact can be opened and closed separately, with isolation function;
The impulse withstand voltage between L pole and N pole can reach up to 6000V;
The impulse withstand voltage between L pole, N pole and the metal support can reach up to 8000V;
It has the ability to bear under the impact current of 200A without misoperation.
1. Protection against overload and short-circuit currents
2. Protection against the effects of sinusoidal alternating earth fault currents
3. Protection against indirect contacts and additional protection against direct contacts
4. Protection against fire hazard caused by insulation faults
5. Used in residential building
6. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln
WPH9-125 Isolating Switch
WPH9-125 series isolating switch is suitable in the resistive circuit of AC 50/60HZ, rated voltage 230/400V, rated current up to 125A. It's used primarily for circuit's turning on or off in non-load ed situation. And it functions on connection and isolation between lines and power, especially suitable to isolate power effectively and prevent circuit breaker from closing accidentally when maintain the circuit in order to ensure the safe operation of maintainer.
Product standard: IEC/EN 60947-3
WPB1-63 MCB
1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln, type D(10-16)ln
WPB2-63 Miniature Circuit Breaker
1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln, type D(10-16)ln
WPB3-63 Mini Circuit Breaker
1. Overload protection
2. Short circuit protection
3. Controlling
4. Used in residential building, non-residential building, energy source industry and infrastructure.
5. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln, type D(10-16)ln
WPB9RL-100 New Design RCD
1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure
WPB8RL-100 6kA Economical RCCB
1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure
WPB1RL-100 Economical Residual Current Circuit Breaker
1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure
WPAF Series Arc Fault Detection Device (AFDD)
AFDD(arc fault detection device) is a new electrical anti-fireequipment. It could avoid various of fires caused by short circuit, circuit aging, heavy load,poor contact, fault electrical devices, etc. Automatic control is realized by built-in computer chip. Its operating principle: the detected arc impulse is processed, compared and identified by electronic circuit and MCU. Once fault arc impulse which easily creates fire detected, the output will drive tripping unit to cut off the load power supply, so that the fire is prevented.
Function
AFDD aims to detect hazardous arc impulse which easily creates fire(such as insulation decreasing between lines, load short circuit, poor contact of connector, arc caused by house electrical apparatus fault).Then it triggers tripping unit to cut off the power supply to prevent electrical fire. AFDDis used together with leakage circuit breaker, low voltage circuit breaker(overcurrent protection)tobuild a multi function electrical protective device. As a true intelligent low voltage electrical apparatus, t can not only prevent electrical fire, electric shock to human, overload danger, etc, but also be customized with different functions.
Application
As per IEC62606, these different ratings available: 10A, 16A, 20A, 32A, 40A, 63A ,usually used in residential houses as a terminal protective device. The applications of AFDD are wide, in theory, it can be used to avoid fire wherever there is electricity, such as in residential house, office building, hospital, shopping mall, supermarket, factory, vehicle(auto, train, vessel, air plane), especially for anti-fire use in residential house.
WPB2RL-100 Residual Current Circuit Breaker
1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure
WPB5RL-100 Residual Current Circuit Breaker
1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure
WPB6RL-100 Residual Current Circuit Breaker
1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure
WPB7RL-100 Residual Current Circuit Breaker
1. Protection against the effects of sinusoidal alternating earth fault currents
2. Protection against indirect contacts and additional protection against direct contacts
3. Protection against fire hazard caused by insulation faults
4. Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry and infrastructure